We specialize in network cabling solutions and optical fiber products integrating design, development, sales and service.
Based on the mature research and development system, the quality stability of Simante has been guaranteed at the design source. We have more than 10 engineers and over 30 full-time technical persons who continue to provide their professional value in the position, improving quality and promoting product update.
Simante provides specialized integrated solutions for customers to ensure it meets the customer's requirement. Welcome to visit.
Core Specification
Patch panel specification differs from a passive jack mainly in rack format, port density, and termination style on the back, since the front-facing port itself still follows the same category standard. The table below lists the parameters Simante's current patch panel range is built around, drawn from its 1U/2U, 24-port/48-port, UTP/FTP, and blank/fixed-category models.
Because blank panels are sold to be populated with a customer's own keystone jacks, their 'category' spec is effectively set by whatever jack is punched into them — this is one of the more common OEM combinations requested: a Simante blank panel paired with a Simante-branded keystone jack line.
| Parameter | Detail |
| Category options | Cat5e, Cat6, Cat6A (fixed-category panels); Voice/25-port Cat3 panel also available |
| Panel format | 1U 24-port, 2U 48-port; 12-port and 0.5U compact formats also produced |
| Frame type | Fixed-category keystone panel, blank/angled panel for customer-supplied keystone jacks |
| Termination type | 110 IDC, Krone IDC, and dual-compatible termination on the rear |
| Shielding | UTP (unshielded) and FTP (360° shielded shell) construction |
| Port orientation | Straight (180°) and angled (90°) port layouts |
| Frame material | Cold-rolled steel frame with powder-coated or plated finish |
| Wiring scheme | T568A / T568B compatible, labeled on the panel face or rear |
| Performance reference | Category electrical performance tested against TIA/EIA-568-C.2 and ISO/IEC 11801 |
Application Scenarios and Target Customers
Patch panels sold under this tag span standard office and campus telecom rooms running Cat5e/Cat6, data center and high-density server rooms specifying shielded Cat6A, and legacy or hospitality voice risers using the 25-port voice/Cat3 panel. Blank and angled panels are typically specified where a project's keystone jack mix is decided separately from the panel order — common on jobs with mixed voice and data drops, or where a customer wants every port on a panel to carry its own branded jack.
The table below sets out which customer type this page is written for and what each one is usually optimizing for when sourcing patch panels from an OEM factory rather than a generic trading company.
| Customer Type | What They Typically Need |
| Importers & brand owners | Private-labeled panel face printing, consistent port-to-port electrical performance, direct factory pricing |
| Regional distributors | A full Cat5e/Cat6/Cat6A range kept in stock with predictable reorder lead times |
| Data center / system integrators | Shielded Cat6A panels, high port density per rack unit, cable-management-friendly rear layout |
| Hotel & project contractors | Voice/25-port panels for guest-room risers alongside data panels for office areas, matched to the project's cabling schedule |
| Chain retailers / e-commerce sellers | Retail-ready packaging and labeling for small-box or marketplace resale |
| Brand owners developing a custom panel | Blank/angled panel frames that accept the customer's own branded keystone jack line, plus custom face printing |
OEM/ODM Customization Capability
Simante's customization process for patch panels follows the same company-wide OEM/ODM workflow used across its product range: a design draft or reference sample is submitted, Simante produces a 3D drawing for confirmation, quotes the project, builds tooling if a new frame shape is needed, produces a physical sample for sign-off, and then moves into mass production with ERP-tracked order status. For a patch panel specifically, most customization requests fall into frame finish, port labeling, and category/termination mix rather than a brand-new mechanical design, since the rack-mount dimensions themselves follow a fixed industry standard.
The table below separates what can usually be adjusted on existing tooling from what requires a new mold or frame design, which is treated as a tooling-development project with its own lead time.
| Customization Item | What Can Be Adjusted |
| Logo / face printing | Custom logo, part number, and port-numbering silkscreen on the panel faceplate |
| Frame finish | Standard plated/powder-coated steel; custom finish color on request |
| Port category mix | Fixed Cat5e / Cat6 / Cat6A, or blank frame populated with customer-selected keystone jacks |
| Termination style | 110 IDC, Krone IDC, or dual-compatible rear termination |
| Shielding | UTP or FTP (360° shielded) construction |
| Packaging & labeling | Custom-printed carton, barcode/label, and multilingual instruction or wiring diagram sheet |
| New frame/mold development | Custom rack-mount frame shape or bracket design built from the customer's drawing or sample; quoted separately |
Production Capacity and Lead Time
Simante was established in 2005 and operates two manufacturing plants totaling more than 9,000 square meters, with over 50 precision production units — including 10 automatic and 20 semi-automatic injection molding machines plus 8 automatic installation machines — supported by 10+ engineers and 30+ full-time technical staff and an in-house testing laboratory. Company-wide annual output is stated at more than 9 million units, exported to 45+ countries and regions across Europe, Australia, Africa, the Middle East, and Southeast Asia.
These figures describe Simante's overall manufacturing base and are a useful reference for assessing order-size capacity. Standard lead time, peak-season lead time, and MOQ for a specific patch panel SKU depend on port count, category, shielding, and customization scope, and should be confirmed directly with Simante's sales team.
| Item | Detail |
| Established | 2005 — 20+ years in network cabling and fiber optic component manufacturing |
| Facility | 9,000 m²+ total factory area across two manufacturing plants |
| Equipment | 50+ precision production units, incl. 10 automatic + 20 semi-automatic injection molding machines and 8 automatic installation machines |
| Technical team | 10+ engineers, 30+ full-time technical staff, in-house testing laboratory |
| Annual output | 9 million+ units per year across the product range |
| Export footprint | 45+ countries and regions across Europe, Australia, Africa, the Middle East, and Southeast Asia |
| Standard lead time | Confirm with Simante sales — quoted per port count, category, and shielding option |
| Peak-season lead time | Confirm with Simante sales — typically longer during seasonal peak periods |
| MOQ | Confirm with Simante sales — varies by panel format and customization scope |
Packaging and Logistics
Simante's factory sits in Yuyao, Ningbo City, Zhejiang Province, roughly 50 km from Ningbo-Zhoushan Port, which keeps sea-freight handling straightforward for both standard and OEM-packaged panel orders. Patch panels are typically individually boxed with corner or edge protection given their rack-mount frame, then packed into export cartons; under OEM/ODM service the inner box, outer carton printing, and included labeling or instruction sheet can all be customized to the buyer's brand.
Exact carton dimensions, units per carton, and container loading counts vary with port count and panel format (1U vs. 2U, for example), so these are confirmed as part of the formal quotation. The fields below describe the categories of information Simante provides at that stage rather than fixed figures.
| Item | Detail |
| Nearest port | Approx. 50 km from Ningbo-Zhoushan Port |
| Standard export packaging | Individually boxed panel with corner/edge protection, packed into export cartons; custom box printing available under OEM/ODM |
| Carton specification | Confirmed per SKU — varies by 1U/2U format and port count |
| Units per carton | Confirmed per SKU at quotation stage |
| Container loading (20GP/40HQ) | Provided with the formal quotation once carton specification is set |
| Common trade terms | FOB Ningbo, CIF, and EXW commonly used; other Incoterms negotiable |
| Shipping modes | Sea freight for bulk/project orders; air or express courier for samples and urgent restocks |
Español
عربى
русский










